SUMITOMO MT Multi-core Optic Connector /SUMITOMO MPO

View: 819 

 SUMITOMO MPO  Series:

6.png  1569377959406657.png

MPO Bare Belt                                                       MPO Cable 


图片2.png     图片3.png

MPO  round cable                                                          24F  MPO Connector


 


Connector A

MPO Female

Connector B

MPO Female

Fiber Mode

MM 50/125um OM3

Test Wavelength

850/1300nm

Polish Type

PC to PC

Minimum Bend Radius

10mm

Insertion Loss

≤0.70dB(0.40dB Typ.)

Return Loss

≥25dB

Attenuation at 850nm

≤2.3dB/km

Attenuation at 1300nm

≤0.6dB/km

Cable Jacket

LSZH

Cable Jacket O.D

3.0mm

Installation Tensile Load

120N

Long-Term Tensile Load

50N

Operating Temperature

-20°C to +70°C

Storage Temperature

-40°C to +85°C


Applications

1. High density cabling data center. 
2. Cabling in communication base station and distribution case. 
3. Jumper connection. 
4. 40G and 100G optics system, QSFP module. 
5. Optical fiber communication system, CATV, LANs and WANs, FTTx

 


Our Quality Control Center

       We use highly reliable testing equipment. Each product must pass 100% test to ensure that all the products are reliable, good consistency and meet the international standards. Here, you can see our equipments and test methods.

QQ图片20190925103916.png

  

QQ图片20190925105038.png

                    QQ图片20190925105053.png

QQ图片20190925104015.png


How to choose the ferrule channels about 8 fibers MPO cable patch cord?

The 8 fiber cable is generally produced by 12 channels MT ferrule. So there are four channels of MT ferrule are unused, the location of the fiber and MT ferrule channels must be confirmed. Generally speaking, Type 2 is used for QSFP-40G-SR4 optic modules.

QQ图片20190925104035.png


According to ANSI-TIA-568-C.3-2008 specifications, Polarity A show as the above figure, Type-A.


QQ图片20190925104051.png


According to ANSI-TIA-568-C.3-2008 specifications, Polarity B show as the above figure, Type-B.


QQ图片20190925104108.png


According to ANSI-TIA-568-C.3-2008 specifications, Polarity C show as the above figure, Type-C.


HTB117XZacrrK1RjSspa763REXXas.png_.webp.jpg

How does the MPO cable patchcord connect to the switch in 40G system?

The MPO cable patch-cord is directly connected to the QSFP-40G-SR4 optic module. Type-B and Female MPO connector is required. The optic module is connected to the switches directly. Show as above the figure.


HTB1BvlIacfrK1RjSszcq6xGGFXap.jpg_.webp.jpg

How to realize high density MPO cabling system?

We produce high quality MPO cable which is widely used in high density cabling systems. In addition to MPO Cable, we also provide MPO Cassette and 19' rack in line with customer needs, for complete the MPO cabling solution.